Operation CHARM: Car repair manuals for everyone.

Test L: The Blower Motor Does Not Operate Correctly - EMTC

PINPOINT TEST L: THE BLOWER MOTOR DOES NOT OPERATE CORRECTLY - EMTC

Normal Operation
Under normal operation, the blower motor is provided a ground from the blower resistor through circuit 755 (BN/WH). The resistor gets a ground from circuit 57 (BK) in the lowest blower setting. In MED-LO and MED-HI the resistor gets a ground through circuit 751 (DB/WH) or 752 (YE/RD), depending on selected speed. In HI, the blower motor is grounded directly through the blower switch from circuit 755 (BN/WH) to circuit 57 (BK). The blower switch receives its ground from circuit 57 (BK).

This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Blower motor resistor
- Blower motor switch


L1-L4:






L4-L6:






L6-L9:






L9-L10: