Operation CHARM: Car repair manuals for everyone.

Test I: The Battery Is Discharged Or Battery Voltage Is Low

PINPOINT TEST I: THE BATTERY IS DISCHARGED OR BATTERY VOLTAGE IS LOW


I1-I4:






I4-I5:






Normal Operation
The generator output voltage is supplied through the positive battery output (B+), circuit SDC14 (RD) terminal on the rear of the generator to the battery and electrical system. During normal operation the charging system warning indicator is off with the key in the ON position and the engine running. The charging system warning indicator is on with the key in the ON position and the engine off.

This pinpoint test is intended to diagnose the following:
- High key-off current drain(s)
- Engine, generator and battery grounds
- Positive battery cable
- Circuit SDC14 (RD) high resistance
- Battery
- Generator