Refrigerant Oil Loss Due to A Large Leak

If the refrigerant charge is abruptly lost due to a large refrigerant leak, approximately 90 ml (3 fl oz) of refrigerant oil will be carried out of the system suspended in the refrigerant. Any failure that caused a abrupt refrigerant discharge will experience this oil loss. Failures that allow the refrigerant to seep or bleed off over time do not experience this oil loss.

Upon replacement of a component that caused a large refrigerant leak, add 90 ml (3 fl oz) of new polyalkaline glycol (PAG) refrigerant oil plus the desired amount of oil for the particular component.