Removal and Installation
If replacement of the pressure cycling switch is necessary, it is important to note that this may be done without removing the refrigerant charge. A service fitting is located in the pressure switch fitting. During replacement of the pressure switch. a new O-ring seal must be installed and the switch assembled to 4.5 Nm (40 lb in.).