120. Turbine Speed Sensor Installation
Turbine Speed Sensor Installation1. Install sensor O-ring (3) onto speed sensor (2).
2. Apply Transjel to O-ring (3).
3. Install speed sensor (2) into the main housing.
4. Install speed sensor bolt (1) into the main housing.
Notice: Refer to Fastener Notice in Service Precautions.
Tighten the bolt to 12 Nm (108 inch lbs.).