Instrument Panel (IP) - Extension Trim Plate Replacement
Instrument Panel (I/P) Extension Trim Plate Replacement
Removal Procedure
Caution: Refer toSIR Caution in Cautions and Notices.
1. Disable the SIR. Refer to SIR Disabling and Enabling Zone 5 in SIR.
2. Remove the knee bolster trim panel. Refer to Knee Bolster Replacement - Right (Knee Bolster Replacement - Right) .
3. Remove the instrument panel (I/P) upper trim pad. Refer to Trim Pad Replacement - Instrument Panel (I/P) Upper (Service and Repair) .
4. Remove the nuts (2) retaining the I/P extension to HVAC duct.
5. Remove the screws (3) from the I/P extension.
6. Remove the I/P extension (1).
Installation Procedure
1. Install the I/P extension (1) to the I/P.
Notice: Refer to Fastener Notice in Cautions and Notices.
2. Install the screws (3).
Tighten the screws (3) to 3 N.m (26 lb in).
3. Install the nuts (2) that retain the HVAC duct to the I/P extension.
Tighten the screws (2) to 3 N.m (26 lb in).
4. Install the I/P upper trim pad. Refer to Trim Pad Replacement - Instrument Panel (I/P) Upper (Service and Repair) .
5. Install the knee bolster trim panel. Refer to Knee Bolster Replacement - Right (Knee Bolster Replacement - Right) .
6. Enable the SIR. Refer to SIR Disabling and Enabling Zone 5 in SIR.