Centrifugal Advance Diagnosis
Centrifugal Advancer Inspection:
1. Remove the distributor cap.
2. Check the centrifugal advance unit by turning the rotor clockwise by hand, then releasing it. It should return quickly and smoothly by spring force.
3. If the centrifugal advance does NOT retun quickly and smoothly, the distributor must be replaced.