Refrigerant Recovery
Fig. 20 Manifold Gauge Set Hose Connections:
The refrigerant system must be discharged using an air conditioning refrigerant recovery and recycling system. After completing any necessary repairs the refrigerant system can then be evacuated and charged using air conditioning service charging station. Service fitting caps are color coded for easy reference. Red cap indicates high side port. Blue cap indicates low side port.
Failure to check for residual oil from previous recovery can result in adding extra oil to the current vehicle being serviced. This will result in reduced performance and possible compressor damage.
1. Start vehicle and run with the A/C On for two minutes, then attach manifold gauge set to the A/C system, Fig. 20. Attach recovery station inlet hose to center fitting of manifold gauge set.
2. Open both valves of manifold gauge set. Ensure refrigerant tank vapor valve and liquid valve are open.
3. Turn main power switch On.
4. Depress compressor start switch. The amber Compressor On light will come on and the compressor will start. The compressor will shutoff automatically when recovery is complete. Wait two minutes and check for pressure rise. If pressure rise occurs, depress compressor start switch to repeat recovery procedure.
5. To drain receiver dehydrator of A/C system oil, open receiver dehydrator pressurizing valve for 15 seconds to allow some compressor discharge pressure back into receiver dehydrator. Open oil drain valve slowly and drain receiver dehydrator. When oil stops draining, close oil drain valve. Do not allow receiver dehydrator to completely depressurize.