Hold-In Test

REMOVE OR DISCONNECT

Hold-In Test:




^ Negative (-) test lead from field coil lead wire solenoid terminal.

Inspect
^ Check that the pinion remains completely in the energized position.
^ If the pinion remains in the energized position, proceed to the "Pinion Return Test".
^ If the pinion does not remain completely energized, replace the starter solenoid.