Operation CHARM: Car repair manuals for everyone.

Component Tests and General Diagnostics

Reopening the SRS Unit circuit for diagnosis

NOTE:
- To prevent damage of the connector cavity, insert the special tool straight into the cavity from the terminal side.
- Before installing the special tool, wash it with neutral detergent, then air blow dry it.
- Do not use the special tool if it is damaged.
- Make sure to remove the special tool before reconnection.




When the SRS unit connector is disconnected, a short circuit is created in the connector to prevent an airbag deployment. The circuit needs to be open sometimes when diagnosis is performed on the system. Insert the special tool(s) (No.070AZ-SAA0100) in the specified cavities when it is necessary to keep the circuit open for diagnosis.