Operation CHARM: Car repair manuals for everyone.

Alternator

MEASUREMENT STANDARD SERVICE LIMIT
Output Amperage 130 Amps
13.5 Volts at normal engine temperature
Coil (rotor) resistance 2.9 k Ohms
At 68 deg.F (20 deg. C)
Slip Ring O.D. 14.4 mm (0.57 in) 14.0 mm (0.55 in)
Brush Length 10.5 mm (0.41 in) 1.5 mm (0.06 in)
Brush Spring Tension 3.2 N (0.33 kgf, 0.73 lbs)