Operation CHARM: Car repair manuals for everyone.

Shift Solenoids B and C

Shift Solenoid Valves B and C Test





1. Remove the starter.
2. Disconnect the shift solenoid valve B or C connector.
3. Measure the resistance between the No. 1 and No. 2 terminals of the shift solenoid valve B or C.
STANDARD: 12 - 25 ohms
4. Replace the shift solenoid valve B or C if the resistance is out of standard.
5. If the resistance is within the standard, connect the No. 2 terminal of the shift solenoid valve B or C connector to the battery positive terminal, and connect the No. 1 terminal to the battery negative terminal. A clicking sound should be heard. Replace the shift solenoid valve B or C if no sound is heard.