Door Lock Switch Test
Door Lock Switch Test1. Remove the door panel.
2. Remove the two screws, then remove the door lock switch.
3. Check for continuity between the terminals.
- There should be continuity between the No.1 and No.2 terminals when the door lock switch is in the LOCK position.
- There should be no continuity between the No.1 and No.2 terminals when the door lock switch is in the neutral position.
- There should be continuity between the No.2 and No.3 terminals when the door lock switch is in the UNLOCK position.
- There should be no continuity between the No.2 and No.3 terminals when the door lock switch is in the neutral position.
- Except LX: There should be continuity between the No.5 (+) and No.4 (-) terminals under all condition.
4. If the continuity is not as specified, replace the switch.