In-Bed Trunk Lid Handle Switch Test/Replacement
In-Bed Trunk Lid Handle Switch Test/Replacement1. Open the in-bed trunk lid, and remove the in-bed trunk lid inner cover.
2. Disconnect the 2P connector (A) from the in-bed trunk lid handle switch (B).
3. Check for continuity between the No. 1 and No. 2 terminal.
- With the handle pushed, there should be continuity.
- With the handle released, there should be no continuity.
4. If the continuity check is not as specified, replace the switch.