Operation CHARM: Car repair manuals for everyone.

Trunk / Liftgate: Testing and Inspection




In-Bed Trunk Lid Main Switch Test/Replacement

1. Remove the glove box. Glove Box Removal/Installation

2. Carefully push the main switch (A) out.

3. Disconnect the 2P connector (B) from the main switch.

4. Check for continuity between terminals No. 1 and No. 2.
- With the main switch ON, there should be continuity.

- With the main switch OFF, there should be no continuity.

5. If the continuity is not as specified, replace the main switch.