Trunk / Liftgate: Testing and Inspection
In-Bed Trunk Lid Main Switch Test/Replacement
1. Remove the glove box. Glove Box Removal/Installation
2. Carefully push the main switch (A) out.
3. Disconnect the 2P connector (B) from the main switch.
4. Check for continuity between terminals No. 1 and No. 2.
- With the main switch ON, there should be continuity.
- With the main switch OFF, there should be no continuity.
5. If the continuity is not as specified, replace the main switch.