Trunk / Liftgate Handle: Testing and Inspection
In-Bed Trunk Lid Handle Switch Test/Replacement
1. Open the in-bed trunk lid, and remove the in-bed trunk lid inner cover. In-Bed Trunk Lid Latch Replacement
2. Disconnect the 2P connector (A) from the in-bed trunk lid handle switch (B).
3. Check for continuity between terminals No. 1 and No. 2.
- With the handle pushed, there should be continuity.
- With the handle released, there should be no continuity.
4. If the continuity is not as specified, replace the switch. Service and Repair