Power Window Control Module: Testing and Inspection
Power Window Control Unit Reset
Reset the power windows after doing any of the following actions:
- Power window regulator replacement or repair
- Power window motor replacement or repair
- Window run channel replacement
- Power window master switch replacement
- Door glass replacement or repair
- Power is removed from the power window master switch or any of the power window switch while the power window timer is ON.
Using the HDS
1. Connect the HDS to the data link connector.
2. Select BODY ELECTRICAL from the SYSTEM SELECT menu.
3. From the BODY ELECTRICAL SYSTEM SELECT menu, select POWER WINDOWS.
4. From the MODE menu, select ADJUSTMENT.
5. From the ADJUSTMENT menu, select WINDOW RESET for driver's window.
6. Follow the prompts on the screen.
7. Confirm that the power window control unit is reset by using the power window AUTO UP and AUTO DOWN function.
Without the HDS
NOTE: Do each bullet in step 4 within 5 seconds of each other.
1. Turn the ignition switch to ON (II).
2. Move the power window all the way down by using the driver's power window DOWN switch.
3. Open the driver's door.
4. Do the following four times before going to step 5:
- Turn the ignition switch to LOCK (0).
- Push and hold the driver's power window DOWN switch.
- Turn the ignition switch to ON (II).
- Release the driver's power window DOWN switch.
5. Confirm that AUTO UP no longer works. If AUTO UP still works, go back to step 1.
6. Move the power window all the way down using the driver's power window DOWN switch.
7. Pull up and hold the driver's power window UP switch until the power window is all the way up, then continue to hold the switch for 1 second.
8. Confirm that the power window control unit is reset by using the power window AUTO UP and AUTO DOWN function. If the power window still does not work in AUTO, repeat the procedure several times, paying close attention to the 5 second time limit between steps.