Operation CHARM: Car repair manuals for everyone.

Climate Control Unit Power And Ground Circuit Troubleshooting




HVAC

Climate Control Unit Power and Ground Circuit Troubleshooting

Climate Control Unit Power and Ground Circuit Troubleshooting

NOTE: Do this troubleshooting procedure only if sent here by symptom troubleshooting.

1. Fuse check:

-1. Check the following fuse.






Is the fuse OK?
-YES- Go to step 2.
-NO- Replace the fuse, and recheck. If the fuse blows again, check for a short in the No. B22 (7.5 A) fuse circuit.

2. Open wire check (IG2 A/C line):

-1. Disconnect the following connector.






-2. Turn the ignition switch to ON (II).

-3. Measure the voltage between test points 1 and 2.










Is there battery voltage?
-YES- The IG2 A/C wire is OK. Go to step 3.
-NO- Repair an open in the wire between the No. B22 (7.5 A) fuse in the under-dash fuse/relay box and the climate control unit.

3. Open wire check (GND line):

-1. Turn the ignition switch to LOCK (0).

-2. Check for continuity between test points 1 and 2.










Is there continuity?
-YES- The GND wire is OK. Replace the climate control unit Climate Control Unit Removal And Installation (Climate Control).
-NO- Check for an open in the wire between the climate control unit and body ground. If the wire is OK, check for poor ground at G502.