Manufacturer Code Charts: 8
Control System DTCs
HVAC DTC Troubleshooting: 8
DTC indicator 8 : A Short in the Recirculation Control Motor Circuit
1. Problem verification:
-1. Turn the ignition switch to LOCK (0), and then back to ON (II).
-2. Do the Self-Diagnostic Function with the HVAC control unit How To Troubleshoot The Heating and A/C Systems.
-3. Check for DTCs.
Is DTC 8 indicated?
-YES- Go to step 2.
-NO- Intermittent failure. Check for loose wires or poor connections on the recirculation control motor circuit.
2. Shorted wire check (RFD-P, SENSOR 5V lines):
-1. Turn the ignition switch to LOCK (0).
-2. Disconnect the following connectors.
-3. Check for continuity between test points 1 and 2 individually.
Is there continuity?
-YES- Repair a short to body ground in the wire(s) between the HVAC control unit and the recirculation control motor.
-NO- The RFD-P and SENSOR 5V wires are OK. Go to step 3.
3. Recirculation control motor check:
-1. Test the recirculation control motor Recirculation Control Motor Test.
Is the recirculation control motor OK?
-YES- Replace the HVAC control unit HVAC Control Unit Removal And Installation.
-NO- Replace the recirculation control motor Recirculation Control Motor Removal And Installation.