CVT Driven Pulley Pressure Control Solenoid Valve Test
CVT Driven Pulley Pressure Control Solenoid Valve Test
1. Remove the air cleaner Service and Repair.
2. Disconnect the solenoid wire harness 8P connector (A).
3. Measure the CVT driven pulley pressure control solenoid valve resistance between solenoid wire harness 8P connector (B) terminals No. 2 and body ground.
4. If the resistance is out of standard, check for open or short in the solenoid wire harness. If the wires are OK, replace the CVT driven pulley pressure control solenoid valve CVT Driven Pulley Pressure Control Solenoid Valve Replacement.
5. Connect a jumper wire from the battery positive terminal to solenoid wire harness 8P connector terminal No. 2, and connect another jumper wire from the battery negative terminal to body ground. A clicking sound should be heard.
6. If no clicking sound is heard, remove the CVT driven pulley pressure control solenoid valve, and clean it, then recheck. Replace the CVT driven pulley pressure control solenoid valve if a problem recurs CVT Driven Pulley Pressure Control Solenoid Valve Replacement.