The A/C Condenser/Radiator Fans Do Not Run At High Speed, But Do Run At Low Speed (With Climate Control)
The A/C condenser/radiator fans do not run at high speed, but do run at low speed
Probable cause: Malfunction in the fan high speed circuit(s).
Do the following troubleshooting as needed:
A/C condenser fan high speed circuit troubleshooting A/C Condenser Fan High Speed Circuit Troubleshooting
Radiator fan high speed circuit troubleshooting Radiator Fan High Speed Circuit Troubleshooting
Also check for
Climate control DTCs How To Troubleshoot The Climate Control System
Also check for
Powertrain DTCs How To Troubleshoot The Fuel And Emissions Systems (Except FFV Model)
Also check for
Blown fuse No. 7 (30 A) and No. 6 (30 A)
Also check for
Poor ground at G202
Also check for
Poor or loose connections at the terminals
Also check for
A/C pressure sensor malfunction
Also check for
Check A/C system pressure A/C System Test