The A/C Condenser/Radiator Fans Do Not Run At High Speed, But Do Run At Low Speed (Without Climate Control)
The A/C condenser/radiator fans do not run at high speed, but do run at low speed
Probable cause: Malfunction in the fan high speed circuit(s).
Do the following troubleshooting as needed:
A/C condenser fan high speed circuit troubleshooting A/C Condenser Fan High Speed Circuit Troubleshooting
Radiator fan high speed circuit troubleshooting Radiator Fan High Speed Circuit Troubleshooting
Also check for
HVAC DTCs How To Troubleshoot The Heating And A/C Systems
Also check for
Powertrain DTCs How To Troubleshoot The Fuel And Emissions Systems (Except FFV Model)
Also check for
Blown fuse No. 7 (30 A) and No. 6 (30 A)
Also check for
Poor ground at G202
Also check for
Poor or loose connections at the terminals
Also check for
A/C pressure sensor malfunction
Also check for
Check A/C system pressure A/C System Test