P0132
DTC P0132 Linear O2 Sensor Circuit High Input (Bank1, Sensor1)DESCRIPTION
The linear oxygen sensor is mounted on the front side of the Catalytic Converter (warm-up catalytic converter) or in the front exhaust pipe, which detects a wide range of air/fuel ratio in the exhaust gas from rich to lean regions. This linear oxygen sensor produces a current that corresponds to a specific air/fuel ratio. The ECM monitors this signal and determines whether the air/fuel mixture is rich or lean. The ECM constantly monitors the HO2S and increases or decreases the fuel injection duration by using the HO2S signal, which is called closed-loop fuel control operation.
DTC Detecting Condition:
Schematic Diagram:
Step 1:
Step 2:
INSPECTION PROCEDURES