Ignition Coil: Testing and Inspection
INSPECT IGNITION COIL1. Measure the primary coil resistance between terminals 1-2 and 1-3.
Measure the primary coil resistance between terminals 1-4, 2-4 and 3-4.
Standard value :
0.58 Ohm ± 10% (2.0)
0.96 Ohm ± 10% (2.7)
2. Measure the secondary coil resistance between the high-voltage terminal for the No.1 and No.4 cylinders, and between the high-voltage terminals for the No.2 and No.3 cylinders.
Standard value :
8.8 kOhm ± 15% (2.0)
12.5 kOhm ± 15% (2.7)
CAUTION: Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the ignition coil.
Measure the secondary coil resistance between the high-voltage terminals for the No.1 and No.4 cylinders, No.2 and No.5 cylinders and No.3 and No.6 cylinders.