Monitor Scantool Data
Monitor Scantool Data
1. Connect scantool to Data Link Connector (DLC).
2. Engine "ON"
3. Monitor the "Humidity Sensor" Parameter on the Scantool.
Fig. 1) The current data in abnormal state.
Fig. 2) DTC B1201.
4. Are the DTC B1201 present and is parameter of "Humidity Sensor" fixed ?
**Parameter of "Humidity Sensor" will be fixed at 10%, if there is any fault in Humidity Sensor