Monitor Scantool Data
Monitor Scantool Data
1. Connect scantool to Data Link Connector (DLC).
2. Engine "ON"
3. Monitor the "DR AIR MIX Potentiometer" Parameter on the Scantool.
Fig. 1) The current data in abnormal state
Fig. 2) DTC B1246
4. Are the DTC B1246 present and is parameter of "DR AIR MIX Potentiometer" fixed ?
**Parameter of "DR AIR MIX Potentiometer" will be fixed at 100% (or any value above 90%), or 0% (or any value below 10%), if there is any fault in DR AIR MIX potentiometer.