General Information
Component Location
General Description
The mode control actuator mounted on heater unit adjusts position of mode door by generating Direction Motor in accordance with signal of A/C control unit. Pressing mode select switch makes the mode control actuator shift in order of vent-> B/L -> floor -> mix.
DTC Description
The ECM sets DTC B2409 if the direction motor doesn't move to intended position within 40 sec (In this case, ECM try to move mode door for 2 sec. 3 times, every 20 sec. before setting DTC)
DTC Detecting Condition
Specification
Schematic Diagram