General Information
Engine
Engine Control - P2626 O2 Sensor Pumping Current Trim Circuit/Open (Bank 1 Sensor 1) - General Information
Component Location
General Description
The linear O2 sensor is mounted on the front side of the Catalytic Converter (warm-up catalytic converter) or in the front exhaust pipe. It detects a wide range of air/fuel ratios in the exhaust gas from the rich to lean regions. This linear O2 sensor produces a current that corresponds to a specific air/fuel ratio. The PCM monitors this signal and determines whether the air/fuel mixture is rich or lean. The PCM constantly monitors the linear O2 sensor and increases or decreases the fuel injection duration using this signal. This is called closed-loop fuel control operation.
DTC Description
The ECM monitors front O2 sensor control circuit (VN) and sets DTC P2243 if front O2 sensor signal stuck is detected.
DTC Detecting Condition
Schematic Diagram
Signal Waveform
1. Voltage in HO2S
Test Condition :Ignition ON, Engine OFF / HO2S disconnected
2. Scan Tool Data
Fig 1) Normal HO2S (B1S1) value with engine warm-up and idling : Approx. 1.5 - 2.0 V
>Signal decreases with rich air/fuel mixture and increases with lean air/fuel mixture
>Fuel cut-off mode : Approx 3.2 V