Repair procedures
Replacement
1. Disconnect the negative (-) battery terminal.
2. Recover the refrigerant with a recovery/charging station.
3. Disconnect A/C pressure transducer connector (3P) (A).
4. Remove the A/C pressure transducer(B).
CAUTION:
- Take care that liquid & suction pipe are not bent.
5. Installation is the reverse order of removal.
TORQUE :10 - 12N.m (1.0 - 1.2kgf.m, 7.4 - 8.8lbf.ft)