Removal

Starter
1. Disconnect the battery negative cable.
2. Disconnect the starter cable (A) from the B terminal (B) on the solenoid (C), then disconnect the connector (D) from the S terminal (E).




3. Remove the 2 bolts holding the starter, then remove the starter.

Tightening torque :
49.0 - 63.7N.m (5.0 - 6.5kgf.m, 36.2 - 47.0lb-ft)


4. Installation is the reverse of removal.
5. Connect the battery negative cable to the battery.