Repair Procedures
Removal and Installation
Starter
1. Disconnect the battery negative cable.
Tightening torque:
(-) terminal : 4.0 - 6.0N.m (0.4 - 0.6kgf.m, 3.0 - 4.4lb-ft)
2. Disconnect the starter cable (A) from the B terminal (B) on the solenoid (C), then disconnect the connector (D) from the S terminal (E).
3. Remove the 2 bolts holding the starter, then remove the starter.
Tightening torque:
42.2 - 53.9N.m (4.3 - 5.5kgf.m, 31.1 - 39.8lb-ft)
4. Installation is the reverse of removal.
5. Connect the battery negative cable to the battery.