W/Harness Inspection
Electronic Stability Control
C2402 Motor Failure - W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness(es) and terminal condition. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
Check for open or short in harness
1. IG "ON"
2. Measure voltage between power terminal of the HECU harness connector and chassis ground.
Specification : Battery voltage
3. Is the measured value within specifications?
Ground Circuit Inspection
Check for open or short in harness
1. IG "OFF"
2. Disconnect HECU connector.
3. Measure resistance between ground terminal of the HECU harness connector and chassis ground.
Specification : Approx. below 1 Ohms
4. Is the measured value within specifications?