W/Harness Inspection
Engine Control
P0204 Injector Circuit/Open-Cylinder 4 - W/Harness Inspection
Terminal and Connector inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found?
Power Circuit Inspection
Check Open or Short in power circuit
1. IG "OFF" and disconnect injector connector.
2. IG "ON".
3. Measure voltage between power terminal of injector harness connector and chassis ground.
Specification : Approx. B+
4. Is the measured voltage within specification?
Control Circuit Inspection
Check Open or Short in control circuit
1. IG "OFF" and disconnect injector connector.
2. IG "ON".
3. Measure voltage between control terminal of injector harness connector and chassis ground.
Specification : Approx 3.5 V
4. Is the measured voltage within specification?