Component Inspection
A6MF2H
P0768 Shift Control Solenoid Valve 'D' Electrical (OD/C) - Component Inspection
Component Inspection
Shift control solenoid valve (OD/C-VFS) Inspection
1. Ignition "OFF".
2. Disconnect "ATM solenoid valve connector.
3. Measure a resistance between "Shift control solenoid valve (OD/C-VFS) " terminal and power at ATM solenoid valve connector.
Specification : 5.1 ± 0.3 Ohms (25 °C) (77 °F)
4. Is the measured resistance within specifications?