Scantool Diagnostics
Electronic Stability Control
C1503 TCS/ESC(ESP) Switch error - Scantool Diagnostics
Monitor GDS Data
1. Connect GDS to Data Link Connector(DLC)
2. IG ON
3. Press the ESC switch.
4. Monitor the "ESC switch" parameter on the GDS.
Specification :ESC switch parameter changed ON / OFF stats.
5. Whenever the switch is pushed, is the ESC off switch's GDS data changed ON/OFF?