ICM (Integrated Circuit Module) Relay Box
Inspection
Rear Blower Motor relay
Check for continuity between the terminals.
1. There should be continuity between the No.16 and No.15 terminals when power and ground are connected to the No.13 and No.14 in the ICM-A.
Cornering Lamp(LH) Relay
Check for continuity between the terminals.
1. There should be continuity between the No.8 and No.20 terminals when power and ground are connected to the No.13 and No.12 in the ICM-A.
Cornering Lamp(RH) Relay
Check for continuity between the terminals.
1. There should be continuity between the No.19 and No.7 terminals when power and ground are connected to the No.13 and No.11 in the ICM-A.
Rear Fog Lamp Relay
Check for continuity between the terminals.
1. There should be continuity between the No.11 and No.10 terminals when power and ground are connected to the No.11 and No.14 in the ICM-B.
Two Turn Unlock Relay
Check for continuity between the terminals.
1. There should be continuity between the No.12 and No.22 terminals when power and ground are connected to the No.21 and No.22 in the ICM-B.
Burglar Alarm Relay
Check for continuity between the terminals.
1. There should be continuity between the No.20 and No.16 terminals when power and ground are connected to the No.17 and No.6 in the ICM-B.