Input Speed Sensor
Inspection
1. Check signal waveform of Input & output speed sensor using the GDS.
Specification:Refer to "Signal Wave Form" section. Testing and Inspection
Removal
1. Remove the valve body assembly.
(Refer to Hydraulic System-"Valve Body"
2. Disconnect the input & output speed sensor connector(A).
3. Remove the input & output speed sensor (B) after removing the bolts(2ea).
Tightening torque:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)
Installation
1. Install in the reverse order of removal.
NOTE:
- Adding Automatic Transaxle Fluid(ATF).