RAS Warning Lamp Does Not Turn Off
RAS WARNING LAMP DOES NOT TURN OFF
Description
RAS system stops (error) when RAS warning lamp turns ON.
RAS WARNING LAMP DOES NOT TURN OFF
Diagnosis Procedure
1.PERFORM SELF-DIAGNOSIS
With CONSULT-III
Perform RAS control unit self-diagnosis.
Is any DTC detected?
YES - Repair or replace the specific malfunctioning parts.
NO - GO TO 2.
2.CHECK RAS WARNING LAMP
With CONSULT-III
Perform the trouble diagnosis of RAS warning lamp. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES - Check that there is no malfunction in each harness connector pin terminal or disconnection.
NO - Repair or replace the specific malfunctioning part.