Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Step 1:
Steps 2 - 3:
Step 4:
DIAGNOSTIC PROCEDURE
SYMPTOM: Ambient sensor circuit is open or shorted. (21 or -21 is indicated on the display as a result of conducting Self-diagnosis STEP 2.)
COMPONENT INSPECTION
Ambient Sensor
After disconnecting ambient sensor harness connector, measure resistance between terminals 2 and 1 at sensor harness side, using the table.
If NG, replace ambient sensor.