Symptom Related Diagnostic Procedures
Work Flow:
WORK FLOW
NOTE:
- When LCU connectors are disconnected for more than 1 minute such as during trouble diagnoses, the "disconnected" data will be memorized by the BCM. (While BCM memorizes the "disconnected" data, IVMS communication diagnosis of CONSULT-II will display "PAST NO RESPONSE".) Therefore, after reconnecting the LCU connectors, erase the memory.
- To erase the memory, perform the procedure below.
Erase the memory with CONSULT-II or turn the ignition switch to "OFF" position and remove 7.5 A fuse [No. [14] located in the fuse block (J/B)].
NOTE:
- Always check remote controller battery before replacing remote controller.
- The panic alarm operation and trunk open operation of multi-remote control system does not activate with the ignition key inserted in the ignition key cylinder.
All Functions Of Remote Control System Do Not Function:
Multi-Remote Controller Does Not Operate A Part Of The Functions:
TROUBLE SYMPTOM
DIAGNOSTIC PROCEDURE 1
NOTE: Remote controller does not function if battery is not set correctly.
DIAGNOSTIC PROCEDURE 2
Part 1:
Part 2:
DIAGNOSTIC PROCEDURE 3
DIAGNOSTIC PROCEDURE 4
DIAGNOSTIC PROCEDURE 5
DIAGNOSTIC PROCEDURE 6
DIAGNOSTIC PROCEDURE 7