Trouble Diagnosis
Work Flow:
WORK FLOW
NOTE:
- When LCU connectors are disconnected for more than 1 minute such as during trouble diagnoses, the "disconnected" data will be memorized by the BCM. (While BCM memorizes the "disconnected" data, IVMS communication diagnosis of CONSULT-II will display "PAST NO RESPONSE".) Therefore, after reconnecting the LCU connectors, erase the memory.
- To erase the memory, perform the procedure below.
Erase the memory with CONSULT-II or turn the ignition switch to "OFF" position and remove 7.5 A fuse [No. [14] located in the fuse block (J/B)].
GROUND CIRCUIT CHECK
POWER SUPPLY CIRCUIT CHECK
NOTE: CONSULT-II (data monitor) may be used to check for the ignition switch input (ACC, ON, START).
DATA LINES CIRCUIT CHECK
Data lines open circuit check
NOTE: When checking data line circuit, disconnect BCM and all LCU connectors.
1. Disconnect BCM and LCU connectors.
2. Check continuity between BCM and LCU terminals.
Data lines short circuit check
1. Disconnect BCM and all LCU connectors.
2. Check continuity between BCM terminal and body ground.
3. Check voltage between BCM terminal and body ground.