With Transmitter Activation Tool
ID REGISTRATION WITH TRANSMITTER ACTIVATION TOOLThis procedure must do after replace transmitter or low tire pressure warning control unit.
1. Turn ignition switch "OFF".
2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Touch "AIR PRESSURE MONITOR", "WORK SUPPORT" and "ID REGIST".
NOTE: If "AIR PRESSURE MONITOR" is not indicated, go to "CONSULT-II Data Link Connector (DLC) Circuit"
4. With the transmitter activation tool (J-45295) pushed against the front-left transmitter position of the tire air valve, press the button then keep 5 seconds.
5. Register the IDs in order from FR LH, FR RH, RR RH or RR LH. When ID registration of each wheel has been completed, a buzzer sounds and hazard warning lamp blinks.
6. After completing all ID registrations, press "END" to complete the procedure.
NOTE: Be sure to register the IDs in order from FR LH, FR RH, RR RH, to RR LH, or the self-diagnostic results display will not function properly.