Refrigerant Pressure Sensor / Switch: Service and Repair
Refrigerant Pressure SensorREMOVAL
1. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
2. Remove front grille. Refer to "FRONT GRILLE".
3. Disconnect connector and remove refrigerant pressure sensor.
CAUTION:
- Secure refrigerant pressure sensor installation pipe with an open-end wrench. Be careful not to deform pipe during the operation.
- Be careful not to damage the core surface of the condenser during the operation.
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION: Replace refrigerant pressure sensor O-ring with a new one. Apply compressor oil prior to installation.
Refrigerant pressure sensor
Tightening torque : 9.8 - 11.7 Nm (1.0 - 1.2 kg-m, 87 - 104 in-lb)