Section 1
Section 1: Connect a battery charger and CONSULT-II to the vehicle.1. Confirm the ignition switch is OFF.
2. Connect a battery charger to the vehicle battery.
Set the charger at a low charge rate (2-amp "trickle charge").
IMPORTANT
You must connect a battery charger to the vehicle battery when performing ABS/VDC reprogramming. Permanent ABS/VDC damage can occur if you don't.
Connecting a vehicle battery charger will maintain:
^ Proper CONSULT-II power supply during reprogramming-very important if the CONSULT-II battery is low.
^ Vehicle battery voltage level-especially on late model vehicles where the cooling fans come on during reprogramming.
3. Connect CONSULT-II to the vehicle using the DLC-II cable with black Converter Box (see Figure 11).
VERY IMPORTANT:
^ Make sure the DLC-II is pushed in straight and fully plugged in to the vehicle connector.
^ Make sure all other DLC-II cable connections (as shown in Figure 11) are connected properly.
CAUTION
^ Infiniti requires the use of essential tools shown in Figure 11 when performing ABS/VDC reprogramming
^ J44200-10 "Pigtail" should not be removed from the CONSULT-II DDL Port. This "Pigtail" allows use of the stronger "quick disconnect" cable set.
^ If cables are very often changed at the DDL Port (base) of the CONSULT-II unit cable connector pin damage may result.
^ If there is connector pin damage ABS/VDC reprogramming may fail. Permanent damage to the ABS/VDC system can occur.
4. Continue with Section 2.