With 4WAS
DETAILED FLOW1.INTERVIEW FROM THE CUSTOMER
It is also important to clarify customer complaints before inspection. First of all, reproduce symptoms, and understand them fully Ask customer about his/her complaints carefully. In some cases, it is necessary to check symptoms by driving vehicle with customer.
CAUTION:
Customers are not professional. It is dangerous to make an easy guess like "maybe the customer means that or "maybe the customer mentions this symptom".
>> GO TO 2.
2.CHECK SYMPTOM
Start the engine.
CAUTION:
Stop the vehicle.
Does 4WAS warning lamp turn ON?
YES >> GO TO 3.
NO >> GO TO 6.
3.PERFORM SELF-DIAGNOSIS (4WAS MAIN CONTROL UNIT)
With CONSULT-III
Perform 4WAS main control unit self-diagnosis.
Is any DTC detected other than "C1930" or "C1931"?
YES >> GO TO 4.
NO >> GO TO 5.
4.PERFORM TROUBLE DIAGNOSIS (4WAS MAIN CONTROL UNIT)
With CONSULT-III
1. Check the error system detected from the self-diagnosis.
CAUTION:
Check the "DATA MONITOR" value of each DTC detected with the self-diagnosis function.
2. Erase 4WAS main control unit self-diagnosis memory.
CAUTION:
^ Never erase the self-diagnosis result (record) history when replacing 4WAS main control unit.
^ Erase the memory of the self-diagnosis results (record) after printing out or recording all the values of "DATA MONITOR".
>> GO TO 5.
5.PERFORM SELF-DIAGNOSIS (4WAS FRONT CONTROL UNIT AND 4WAS MAIN CONTROL UNIT)
With CONSULT-III
1. Perform 4WAS front control unit self-diagnosis.
2. Check the error system detected from the self diagnosis.
CAUTION:
Check the "DATA MONITOR" value of each DTC detected with the self-diagnosis function.
3. Erase 4WAS front control unit self-diagnosis memory
CAUTION:
^ Never erase the self-diagnosis result (record) history when replacing 4WAS front control unit.
^ Erase the memory of the self-diagnosis results (record) after printing out or recording all the values of "DATA MONITOR".
4. Perform 4WAS main control unit self-diagnosis.
5. Check the error system detected from the self-diagnosis.
CAUTION:
Check the "DATA MONITOR" value of each DTC detected with the self-diagnosis function.
6. Erase 4WAS main control unit self-diagnosis memory
CAUTION:
^ Never erase the self-diagnosis result (record) history when replacing 4WAS main control unit.
^ Erase the memory of the self-diagnosis results (record) after printing out or recording all the values of "DATA MONITOR".
>> GO TO 6.
6.CHECK TERMINAL
Check each harness connector pin terminal for disconnection.
>> GO TO 7.
7.CHECK SYMPTOM REPRODUCTION
With CONSULT-III
Perform DTC reproduction procedure for the error system.
Is any error system detected?
YES >> GO TO 2.
NO >> GO TO 8.
8. PERFORM SYMPTOM DIAGNOSIS
With CONSULT-III
Perform the symptom diagnosis for each system.
Is any error detected?
YES >> GO TO 2.
NO >> GO TO 9.
9.FINAL CHECK
With CONSULT-III
Check input/output signal standard of 4WAS front control unit and 4WAS main control unit.
Is the input/output the standard value?
YES >> INSPECTION END
NO >> GO TO 2.