Component Function Check
INTERIOR ROOM LAMP CONTROL CIRCUIT
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following is normal.
- Interior room lamp power supply
- Map lamp bulb
- Personal lamp bulb
- Foot lamp bulb
1.CHECK INTERIOR ROOM LAMP CONTROL FUNCTION
CONSULT-III ACTIVE TEST
1. Switch the map lamp switch to DOOR.
2. Turn ignition switch ON.
3. Select "INT LAMP" of BCM (INT LAMP) active test item.
4. With operating the test items, check that each interior room lamp turns ON/OFF (gradual brightening/dimming).
On : Interior room lamp gradual brightening
Off : Interior room lamp gradual dimming
Does the interior room lamp turns ON/OFF (gradual brightening/dimming)?
YES - Interior room lamp control circuit is normal.
NO - Refer to Diagnosis Procedure.