Component Function Check
ROOM LAMP REQUEST SIGNAL CIRCUIT
Component Function Check
1.CHECK ROOM LAMP TIMER SETTING
CONSULT-III WORK SUPPORT
1. Select "SET I/L D-UNLCK INTCON" of BCM (INT LAMP) work support item.
2. Check the setting status.
Is the setting "On"?
YES - GO TO 2.
NO - Change the setting to "On"
2.CHECK ROOM LAMP TIMER SIGNAL BY CONSULT-III
CONSULT-III DATA MONITOR
1. Turn ignition switch OFF.
2. Select "ROOM LAMP REQ" of TOTAL ILLUM C/U data monitor item.
3. While operating the door lock/door unlock, check the monitor status.
Is the item status normal?
YES - Room lamp timer signal circuit is normal.
NO - Refer to Diagnosis Procedure.