P1610
P1610 LOCK MODE
Description
When the starting operation is carried more than five times consecutively under the following conditions, NATS will shift to the mode which prevents the engine from being started.
- Unregistered Intelligent Key is used.
- BCM or ECM is malfunctioning.
DTC Logic
DTC DETECTION LOGIC
DTC Detection Logic:
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check "Self diagnostic result" with CONSULT-III.
Is DTC detected?
YES - Go to P1610.
NO - INSPECTION END
Diagnosis Procedure
1.CHECK ENGINE START FUNCTION
1. Perform the check for DTC except DTC P1610.
2. Use CONSULT-III to erase DTC after fixing.
3. Turn ignition switch OFF.
4. Turn ignition switch ON when registered Intelligent Key insert into key slot and wait for 5 seconds.
5. Turn the ignition switch OFF and wait 5 seconds.
6. Repeat steps 4 and 5 twice (total of 3 cycles).
7. Check that engine can start when registered Intelligent Key is inserted into key slot.
- INSPECTION END