S Connector Circuit
S CONNECTOR CIRCUIT
Description
The starter motor magnetic switch is supplied with power when the ignition switch is turned to the START posi- tion while the selector lever is in the P or N position.
S CONNECTOR CIRCUIT
Diagnosis Procedure
CAUTION:
Perform diagnosis under the condition that engine cannot start by the following procedure.
1. Remove fuel pump fuse.
2. Crank or start the engine (where possible) until the fuel pressure is released.
1.CHECK "S" CONNECTOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect starter motor connector.
3. Shift A/T selector lever to "P" or "N" position.
4. Check voltage between starter motor harness connector and ground.
Is the inspection result normal?
YES - "S" connector circuit is OK. Further inspection is necessary. Refer to Initial Inspection and Diagnostic Overview.
NO - GO TO 2.
2.CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
1. Disconnect IPDM E/R connector.
2. Check continuity between starter motor harness connector and IPDM E/R harness connector.
Is the inspection result normal?
YES - Further inspection is necessary. Refer to Initial Inspection and Diagnostic Overview.
NO - Repair the harness.