Microphone
POWER SUPPLY AND GROUND CIRCUIT
MICROPHONE : Diagnosis Procedure
1.CHECK POWER SUPPLY CIRCUIT
Check voltage between microphone harness connector R109 terminal 4 and ground.
Is approximately 5V present?
YES - GO TO 3.
NO - GO TO 2.
2.CHECK POWER SUPPLY CIRCUIT (CONTINUITY)
1. Turn ignition switch OFF.
2. Disconnect microphone and AV control unit harness connectors.
3. Check continuity between microphone harness connector R109
(A) terminal 4 and AV control unit harness connector M45 (B) terminal 70.
4. Check continuity between microphone harness connector R109
(A) terminal 4 and ground.
Are the continuity test results as specified?
YES - Replace the AV control unit. Refer to Service and Repair.
NO - Repair harness or connector.
3.CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect microphone harness connector R109 and AV control unit harness connector M45.
3. Check continuity between microphone harness connector R109
(A) terminal 2 and AV control unit harness connector M45 (B) terminal 71.
Does continuity exist?
YES - Inspection End.
NO - Repair harness or connector.